Gingiva former (TA):

  • for gingival forming
  • 1.5 ° cone for a bacteria-proof connection and bone and papilla preservation
  • Two-piece gingiva former in peek with separate screw available 
  • Abutments can be prepped 
  • Tightening Torque: 10 Ncm (2 mm Platform), 15 Ncm (3 mm & Short Platform)

 

    

Provisional Abutments (PA):

  • for making a temporary denture
  • No clamp connection to the implant for easier manipulation of the structure
  • can be customized individually
  • Precisely fitting snap caps for closed impressions via transfer posts as well as direct abutment impression
  • Gingivaformer cap as well as modeling caps as a temporary restoration are available Gingiva height (GH) of 1.5 mm
  • Tightening Torque: 5 -10 Ncm (2 mm Platform) / 10-15 Ncm (3 mm & Short Platform)

 

    

Preform Abutments (EAK):

  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • can be customized individually
  • Precisely fitting snap caps for closed impressions via transfer posts as well as direct abutment impression
  • Circular construction panel meets the highest aesthetic standards
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Anatomic Abutments (AA):

  • for producing a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • can be individually prepped
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Anatomical gingiva course of the abutment meets the highest aesthetic demands
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Freeform Abutments (FF):

  • for producing an individual ligation structure with its own emergence profile, step or groove from a blank by manual processing (milling) of the technician
  • should and must be prepared
  • Anti-rotation of the crowns by groove and recess on the body
  • for incisor. and canine area on 2 mm platform and all areas on 3 mm platform
  • for crowns, bridges and telescopic structures
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm, for 3 mm Platform & 15 - 20 with Short Platform

 

    

Castable Aufbauten (UCLA):

  • For producing an individual alloy structure over the sprue with an individual emergence profile
  • Construction for front and canine area with 2 mm platform and all areas with 3 mm platform
  • For the production of a cemented denture
  • Custom-fit burnout POM caps
  • Abutment height provides a secure connection of the sprue construction
  • Retentive depressions on the base structure with flattening as anti-rotation protection of the burn-out POM cap for individual wax modeling
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Circular construction panel meets the highest aesthetic standards
  • Gingiva height (GH): 1.5 mm
  • Suitable for telescopic crowns as well as individual modulation
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

    

Base Abutments (GAT):

  • for the production of an individual zirconia Abutment by copying process with its own emergence profile
  • The circular shape of the Abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the zirconium abutment by flattening the base structure
  • abutment height ensures good bond strength of the milled zirconium structure
  • Precisely fitting PEEK caps for data milling
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

   

Scan/Glue Abutments (KSA):

  • for the production of an individual zirconia abutment in the CAD-CAM process with its own emergence profile
  • Scanbody or Scancap for digitizing the structure
  • the circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the zirconium structure by cam on the base structure
  • Construction height ensures good bond strength of the milled zirconium structure
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Cerec Abutments (CS):

  • for the production of an individual zirconia abutment in the CAD-CAM process with its own emergence profile
  • Precisely fitting Cerec scan cap for digitizing the abutment (Omni and Bluecam cap available)
  • the circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of hybrid abutments
  • for incisor and canine area on 2 mm platform and all areas on 3 mm & Short Platform
  • Anti-rotation of the zirconium structure by cam on the base structure
  • Abutment height ensures good bond strength of the milled zirconium structure
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 -20 Ncm (2 mm Platform) / 25-30 Ncm, for 3 mm Platform & 15-20 with Short Platform

 

 

Emergence Abutments (EAZ):

  • for the production of a screw-retained denture with its own emergence profile
  • The circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for producing a screwed or cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the crown due to the oval shape of the base structure
  • Abutment height ensures good adhesion or screw strength
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

RapidFix Abutments (VBA):

  • for removable or screw-retained dentures for crowns, bridges and bars
  • implant-supported RapidFix screwed supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: Two-piece construction with index
  • Abutment screw with external hexagon for screwing in and internal thread for fixing the abutment with a short screw
  • Analog and CAD suitable (data set integrated in K3Pro® library)
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform
  •  
          

Multi Base Abutments (MB):

  • for the removable or screw-retained dentures
  • Implant-supported bar supply
  • 1.5 ° conical connection for a bacteria-proof connection and bone and papilla preservation
  • Solid abutment: two-piece design without index with screw for fixation of abutment and abutment with implant (one continuous screw)
  • Analog and CAD suitable (data set integrated in K3Pro® library)
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm (3 mm & Short Platform)

 

    

Finder Abutments (FLA):

  • for removable dentures
  • Mucosal and implant-supported locator supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: one-piece construction with integrated screw
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 20 - 30 Ncm (3 mm & Short Platform)

 

 

O-Ring Abutments (KKA):

  • for removable dentures
  • Mucosa-supported O-ring supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: one-piece construction with integrated screw
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 20 - 30 Ncm (3 mm & Short Platform)

 

      

Orthodontic Abutments (KFO):

  • for orthodontic treatment
  • for palate/ short implants
  • secondary caps can be individually prepared
  • circular abutment shoulder allows exact fit of the secondary cap
  • Tightening torque: 15 - 20 Ncm (Short Platform)

 

     