Gingiva former (TA):

  • for gingival forming
  • 1.5 ° cone for a bacteria-proof connection and bone and papilla preservation
  • Two-piece gingiva former in peek with separate screw available 
  • Abutments can be prepped 
  • Tightening Torque: 10 Ncm (2 mm Platform), 15 Ncm (3 mm & Short Platform)

 

    

Provisional Abutments (PA):

  • for making a temporary denture
  • No clamp connection to the implant for easier manipulation of the structure
  • can be customized individually
  • Precisely fitting snap caps for closed impressions via transfer posts as well as direct abutment impression
  • Gingivaformer cap as well as modeling caps as a temporary restoration are available Gingiva height (GH) of 1.5 mm
  • Tightening Torque: 5 -10 Ncm (2 mm Platform) / 10-15 Ncm (3 mm & Short Platform)

 

    

Preform Abutments (EAK):

  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • can be customized individually
  • Precisely fitting snap caps for closed impressions via transfer posts as well as direct abutment impression
  • Circular construction panel meets the highest aesthetic standards
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Anatomic Abutments (AA):

  • for producing a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • can be individually prepped
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Anatomical gingiva course of the abutment meets the highest aesthetic demands
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Freeform Abutments (FF):

  • for producing an individual ligation structure with its own emergence profile, step or groove from a blank by manual processing (milling) of the technician
  • should and must be prepared
  • Anti-rotation of the crowns by groove and recess on the body
  • for incisor. and canine area on 2 mm platform and all areas on 3 mm platform
  • for crowns, bridges and telescopic structures
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm, for 3 mm Platform & 15 - 20 with Short Platform

 

    

Castable Aufbauten (UCLA):

  • For producing an individual alloy structure over the sprue with an individual emergence profile
  • Construction for front and canine area with 2 mm platform and all areas with 3 mm platform
  • For the production of a cemented denture
  • Custom-fit burnout POM caps
  • Abutment height provides a secure connection of the sprue construction
  • Retentive depressions on the base structure with flattening as anti-rotation protection of the burn-out POM cap for individual wax modeling
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Circular construction panel meets the highest aesthetic standards
  • Gingiva height (GH): 1.5 mm
  • Suitable for telescopic crowns as well as individual modulation
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

    

Base Abutments (GAT):

  • for the production of an individual zirconia Abutment by copying process with its own emergence profile
  • The circular shape of the Abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the zirconium abutment by flattening the base structure
  • abutment height ensures good bond strength of the milled zirconium structure
  • Precisely fitting PEEK caps for data milling
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

   

Scan/Glue Abutments (KSA):

  • for the production of an individual zirconia abutment in the CAD-CAM process with its own emergence profile
  • Scanbody or Scancap for digitizing the structure
  • the circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of a cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the zirconium structure by cam on the base structure
  • Construction height ensures good bond strength of the milled zirconium structure
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

Cerec Abutments (CS):

  • for the production of an individual zirconia abutment in the CAD-CAM process with its own emergence profile
  • Precisely fitting Cerec scan cap for digitizing the abutment (Omni and Bluecam cap available)
  • the circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for the production of hybrid abutments
  • for incisor and canine area on 2 mm platform and all areas on 3 mm & Short Platform
  • Anti-rotation of the zirconium structure by cam on the base structure
  • Abutment height ensures good bond strength of the milled zirconium structure
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 -20 Ncm (2 mm Platform) / 25-30 Ncm, for 3 mm Platform & 15-20 with Short Platform

 

 

Emergence Abutments (EAZ):

  • for the production of a screw-retained denture with its own emergence profile
  • The circular shape of the abutment recesses enables ideal design freedom for the highest aesthetic demands
  • for producing a screwed or cemented denture
  • for incisor and canine area with 2 mm platform
  • for all areas at 3 mm & Short Platform
  • Anti-rotation of the crown due to the oval shape of the base structure
  • Abutment height ensures good adhesion or screw strength
  • 1.5 ° conical connection for maximum stability and bacteria tightness
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform

 

 

RapidFix Abutments (VBA):

  • for removable or screw-retained dentures for crowns, bridges and bars
  • implant-supported RapidFix screwed supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: Two-piece construction with index
  • Abutment screw with external hexagon for screwing in and internal thread for fixing the abutment with a short screw
  • Analog and CAD suitable (data set integrated in K3Pro® library)
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform), 25 - 30 Ncm for 3 mm Platform & 15 - 20 with Short Platform
  •  
          

Multi Base Abutments (MB):

  • for the removable or screw-retained dentures
  • Implant-supported bar supply
  • 1.5 ° conical connection for a bacteria-proof connection and bone and papilla preservation
  • Solid abutment: two-piece design without index with screw for fixation of abutment and abutment with implant (one continuous screw)
  • Analog and CAD suitable (data set integrated in K3Pro® library)
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 25 - 30 Ncm (3 mm & Short Platform)

 

    

Finder Abutments (FLA):

  • for removable dentures
  • Mucosal and implant-supported locator supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: one-piece construction with integrated screw
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 20 - 30 Ncm (3 mm & Short Platform)

 

 

O-Ring Abutments (KKA):

  • for removable dentures
  • Mucosa-supported O-ring supply
  • 1.5 ° conical connection for a bacteria - proof connection and bone and papilla preservation
  • Solid abutment: one-piece construction with integrated screw
  • Abutments can not be prepped
  • Tightening torque: 15 - 20 Ncm (2 mm Platform) / 20 - 30 Ncm (3 mm & Short Platform)

 

      

Orthodontic Abutments (KFO):

  • for orthodontic treatment
  • for palate/ short implants
  • secondary caps can be individually prepared
  • circular abutment shoulder allows exact fit of the secondary cap
  • Tightening torque: 15 - 20 Ncm (Short Platform)

 

     

News

In our Implant Solutions milling and planning center, we offer surgical and prosthetic planning as well as 3D printing for models and surgical guides. To perform the work at Implant Solutions, a digital image of the patient's jaw in the DVT center is necessary. On the basis of these data, the production takes place a three-dimensional drilling template. This template, with an accuracy of about 0.1 mm, contributes to a significant improvement in prosthetics and surgery. Furthermore, Implant Solutions mills individual abutments made of zirconium dioxide or titanium, not only for K3Pro® implants, but also for many others Implant systems.